Location
-
EI-Direktinjetions-Q1-MS
Single quadrupole MS with sample direct inlet DIP and DEP as well as EI and CI ionization.
graphics: as jpg, png, ai, eps, svg as zip-filezip, 4 mb · de
text for publication (docx-Document)docx, 13 kb · de
location: IAAC, MS platform de -
LC-QTOF-MS Bruker Maxis
Bruker Maxis Q-Tof mass spectrometer coupled to a Dionex Ultimate3000 UHPLC system with binary pump, autosampler, 6-fold column changer and VWD or an Agilent 1100 HPLC with binary pump and fluorescence detector. Ionization with ESI.
graphics: as jpg, png, ai, eps, svg as zip-filezip, 18 mb · de
text for publication (docx document)
location: IAAC, MS platform de -
LC-Trap-MS Thermo LTQ
Thermo LTQ ion trap mass spectrometer coupled to an Agilent 1100 HPLC system with binary pump, autosampler, column thermostat and VWD, primarily for the measurement of reaction controls. Ionization with ESI or APCI possible.
graphics: as jpg, png, ai, eps, svg as zip filezip, 11 mb · de
text for publication (docx document)docx, 28 kb · de
location: IAAC, MS platform de -
GC-Trap-MS Thermo ITQ900
Thermo ITQ900 mass spectrometer coupled to a Trace 1300 GC chromatograph with S/SL injection system and AS3000 autosampler. Primarily for the measurement of dissolved samples, for example reaction controls. Ionization is possible with EI.
graphics: as jpg, png, ai, eps, svg as zip filezip, 5 mb · de
text for publication (docx document)docx, 13 kb · de
location: IAAC, MS platform de -
GC ion trap MS
Thermo Polaris Q mass spectrometer coupled to a GC chromatograph Trace 1300 with S/SL and PTV injection system and autosampler CTC CombiPal. Primarily for the measurement of (very) volatile samples. Ionization is possible with EI or CI.
graphics: as jpg, png, ai, eps, svg as zip filezip, 5 mb · de
text for publication (docx document)docx, 15 kb · de
location: IAAC, MS platform de -
MALDI TOF
Bruker Ultraflextreme MALDI TOF/TOF, primarily for polymer and peptide analysis.
graphics: as jpg, png, ai, eps, svg as zip filezip, 2 mb · de
text for publication (docx document)docx, 16 kb · de
location: IAAC, MS platform de -
nanoLC Orbitrap Fusion
Orbitrap Fusion mass spectrometer with a Dionex Ultimate 3000 nano-HPLC and nano-ESI ionization.
graphics: as jpg, png, ai, eps, svg as zip filezip, 11 mb · de
location: IAAC, Dr. Lakemeyer groupExternal link
-
UHPLC-Orbitrap
Thermo Q-Exactive plus mass spectrometer coupled to an Ultimate3000 UHPLC system with binary pump, autosampler, 6-position column changer and DAD. Ionization options include ESI, APCI, AP-MALDI or nano ESI.
graphics: as jpg, png, ai, eps, svg as zip file.zip, 12 mb · de
text for publication (docx document)docx, 19 kb · de
text for acknowledgement. txt, 166 b · de
location: TO, Pohnert groupExternal link -
UHPLC-Q1-MS
Thermo ISQ-EC mass spectrometer coupled to an Ultimate3000 UHPLC system with binary pump, autosampler, 6-fold column changer and VWD. Ionization with ESI.
graphics: as jpg, png, ai, eps, svg as zip-Datei.zip, 10 mb · de
location: TO, Pohnert groupExternal link -
GC-Q1-MS
Thermo ISQ coupled to a GC chromatograph Trace 1300 with S/SL injection system and autosampler AS3000. Ionization is possible with EI.
graphics: as jpg, png, ai, eps, svg as zip file.zip, 5 mb · de
location: TO, Pohnert groupExternal link -
GC-Q3-MS
Thermo TSQ8000 coupled to a Trace 1310 GC chromatograph with S/SL or PTV injection system and Triplus RSH liquid handling autosampler. Ionization is possible with EI or CI.
graphics: as jpg, png, ai, eps, svg as zip file.zip, 4 mb · de
text for acknowledgement.txt, 153 b · de
location: TO, Pohnert groupExternal link -
GC-Orbitrap
Thermo Q-Exactive GC coupled to a Trace 1310 GC chromatograph with S/SL or PTV injection system and Triplus RSH liquid handling autosampler. Ionization is possible with EI or CI.
graphics: as jpg, png, ai, eps, svg as zip file.zip, 5 mb · de
text for publication (docx document)docx, 13 kb · de
text for acknowledgement.txt, 147 b · de
location: TO, Pohnert groupExternal link -
UHPLC Exploris 480
Thermo Exploris 480 plus mass spectrometer coupled to a Vanquish UHPLC system with binary pump, autosampler, 6-fold column changer and DAD. Ionization option is ESI.
graphics: as jpg, png, ai, eps, svg as zip file.zip, 11 mb · de
text for publication (docx document)docx, 17 kb · de
text for acknowledgementtxt, 220 b · de
location: TO, Pohnert groupExternal link
-
MALDI-TOF
Bruker UltraFlex III MALDI TOF/TOF.
graphics: as jpg, png, ai, eps, svg as zip filezip, 2 mb · de
text for publication (docx document)docx, 16 kb · de
location: ZAF, Schubert group de -
LC-Q-TOF
Bruker microTofQ coupled to an Agilent 1200 HPLC system with autosampler. Ionization is possible with ESI or APCI.
graphics: as jpg, png, ai, eps, svg as zip filezip, 12 mb · de
location: ZAF, Schubert group de -
MALDI-TOF Bruker Rapiflex
Bruker Rapiflex MALDI TOF/TOF.
graphics: as jpg, png, ai, eps, svg as zip filezip, 3 mb · de
text for acknowledgement txt, 104 b · de
text for publication (docx document)docx, 16 kb · de
location: ZAF, Schubert group de -
LC Tims-TOF MS (Bruker)
Bruker timsTOF mass spectrometer coupled to an Ultimate3000 UHPLC system with binary pump, autosampler, 2-fold column changer and DAD. Ionization capabilities include ESI and APCI.
graphics: as jpg, png, ai, eps, svg as zip filezip, 11 mb · de
text for acknowledgement. txt, 103 b · de
location: ZAF, Schubert group de
Location
IOMC Humboldtstraße 10 de: Arndt GroupExternal link and junior group LakemeyerExternal link
-
LC-Q-TOF
Bruker maxis impact (QTOF) coupled to a Thermo Ultimate 3000 quaternary UHPLC system with autosampler, 2-fold column changer and DAD. Ionization is ESI.
graphics: as jpg, png, ai, eps, svg as zip filezip, 12 mb · de
textpassage for publication (docx document)docx, 29 kb · de
location: IOMC, Arndt groupExternal link -
LC-Trap-MS
Finnigan MAT ion trap mass spectrometer coupled to a Shimadzu HPLC system.
location: IOMC, Arndt groupExternal link
-
GC-Q1-MS
Agilent single quadrupole mass spectrometer coupled to an HP gas chromatograph.
location: IOMC, Arndt groupExternal link
-
LC-LTQ
Thermo LTQ ion trap mass spectrometer coupled to a Thermo Ultimate 3000 quaternary UHPLC system with autosampler, 2-fold column changer and DAD. Ionization is ESI.
graphics: as jpg, png, ai, eps, svg as zip filezip, 12 mb · de
location: IOMC, Dr. Lakemeyer group External link